Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Clinics ; 73: e182, 2018. tab
Artigo em Inglês | LILACS | ID: biblio-952799

RESUMO

OBJECTIVES: To compare the results respectively obtained from the utilization of 60% barium sulfate suspension and Iohexol as contrast agents for videofluoroscopic swallowing studies and the relationship between the clinical application of the two kinds of contrast agents and the incidence of pneumonia. METHODS: Sixty cases of stroke patients with dysphagia were selected in rehabilitation department of our hospital, and the gender, age, position of the disease, and stroke nature between groups had no significant difference. Among which, 30 patients who were administered 350 mgI/ml Iohexol, and the other 30 patients with 60% barium sulfate suspension as contrast agent. We performed videofluoroscopic swallowing studies with barium 60% versus Iohexol within 1 week after admission and 2 weeks after admission. RESULTS: After 2 weeks in hospital, the aspiration pneumonia incidence of two groups was statistically significant (p<0.05), the pneumonia incidence of Iohexol group was lower than barium sulfate group which might have a impossble relevance with barium aspiration. CONCLUSIONS: During the videofluoroscopic swallowing study of dysphagia after stroke, barium sulfate can enhance the pneumonia incidence, and Iohexol can be widely applied in videofluoroscopic swallowing study.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Pneumonia Aspirativa/induzido quimicamente , Sulfato de Bário/efeitos adversos , Fluoroscopia/métodos , Transtornos de Deglutição/diagnóstico por imagem , Meios de Contraste/efeitos adversos , Pneumonia Aspirativa/diagnóstico , Sulfato de Bário/administração & dosagem , Gravação em Vídeo/métodos , Iohexol/administração & dosagem , Iohexol/efeitos adversos , Transtornos de Deglutição/complicações , Meios de Contraste/administração & dosagem , Deglutição/efeitos dos fármacos , Reabilitação do Acidente Vascular Cerebral/métodos
3.
Korean Journal of Radiology ; : 183-193, 2013.
Artigo em Inglês | WPRIM | ID: wpr-15370

RESUMO

OBJECTIVE: To investigate the validity of the 100 kVp setting in CT venography (CTV) in the diagnosis of deep vein thrombosis (DVT), and to evaluate the feasibility of reducing the amount of administered iodine in this setting. MATERIALS AND METHODS: After receiving the contrast medium (CM) of 2.0 mL/kg, 88 patients underwent CTV of the pelvis and lower extremities by using one of four protocols: Group A, 120 kVp setting and 370 mgI/mL CM; group B, 120 kVp and 300 mgI/mL; group C, 100 kVp and 370 mgI/mL; group D, 100 kVp and 300 mgI/mL. The groups were evaluated for venous attenuation, vein-to-muscle contrast-to-noise ratio (CNRVEIN), DVT-to-vein contrast-to-noise ratio (CNRDVT), and subjective degree of venous enhancement and image quality. RESULTS: Venous attenuation and CNRVEIN were significantly higher in group C (144.3 Hounsfield unit [HU] and 11.9), but there was no significant difference between group A (118.0 HU and 8.2) and D (122.4 HU and 7.9). The attenuation value of DVT was not significantly different among the four groups, and group C had a higher absolute CNRDVT than the other groups. The overall diagnostic image quality and venous enhancement were significantly higher in group C, but there was no difference between groups A and D. CONCLUSION: The 100 kVp setting in CTV substantially help improve venous enhancement and CNRVEIN. Furthermore, it enables to reduce the amount of administered iodine while maintaining venous attenuation, as compared with the 120 kVp setting.


Assuntos
Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Iohexol/administração & dosagem , Modelos Lineares , Extremidade Inferior/irrigação sanguínea , Imagens de Fantasmas , Flebografia/métodos , Estatísticas não Paramétricas , Tomografia Computadorizada por Raios X/métodos , Trombose Venosa/diagnóstico por imagem
4.
Korean Journal of Radiology ; : 235-243, 2009.
Artigo em Inglês | WPRIM | ID: wpr-101657

RESUMO

OBJECTIVE: This study was conducted to assess the feasibility of performing 100-kVp electrocardiogram (ECG)-gated coronary CT angiography, as compared to 120-kVp ECG-gated coronary CT angiography. MATERIALS AND METHODS: We retrospectively evaluated one hundred eighty five gender- and body mass index-matched 16-slice coronary CT sets of data, which were obtained using either 100 kVp and 620 effective mAs or 120 kVp and 500 effective mAs. The density measurements (image noise, vessel density, signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]) and the estimated radiation dose were calculated. As a preference test, two image readers were independently asked to choose one image from each pair of images. The results of both protocols were compared using the paired t-test or the Wilcoxon signed rank test. RESULTS: The 100-kVp images showed significantly more noise and a significantly higher vessel density than did the 120-kVp images. There were no significant differences in the SNR and CNR. The estimated reduction of the radiation dose for the 100-kVp protocol was 24%; 7.8 +/- 0.4 mSV for 100-kVp and 10.1 +/- 1.0 mSV for 120-kVp (p < 0.001). The readers preferred the 100-kVp images for reading (reader 1, p = 0.01; reader 2, p = 0.06), with their preferences being stronger when the subject's body mass index was less than 25. CONCLUSION: Reducing the tube kilovoltage from 120 to 100 kVp allows a significant reduction of the radiation dose without a significant change in the SNR and the CNR.


Assuntos
Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Eletrocardiografia/métodos , Estudos de Viabilidade , Iohexol/administração & dosagem , Variações Dependentes do Observador , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
5.
Korean Journal of Radiology ; : 285-293, 2009.
Artigo em Inglês | WPRIM | ID: wpr-101651

RESUMO

Fenestrated endovascular repair of an abdominal aortic aneurysm has been developed to treat patients with a short or complicated aneurysm neck. Fenestration involves creating an opening in the graft fabric to accommodate the orifice of the vessel that is targeted for preservation. Fixation of the fenestration to the renal arteries and the other visceral arteries can be done by implanting bare or covered stents across the graft-artery ostia interfaces so that a portion of the stent protrudes into the aortic lumen. Accurate alignment of the targeted vessels in a longitudinal aspect is hard to achieve during stent deployment because rotation of the stent graft may take place during delivery from the sheath. Understanding the 3D relationship of the aortic branches and the fenestrated vessel stents following fenestration will aid endovascular specialists to evaluate how the stent graft is situated within the aorta after placement of fenestrations. The aim of this article is to provide the 2D and 3D imaging appearances of the fenestrated endovascular grafts that were implanted in a group of patients with abdominal aortic aneurysms, based on the multislice CT angiography. The potential applications of each visualization technique were explored and compared with the 2D axial images.


Assuntos
Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Prótese Vascular , Meios de Contraste/administração & dosagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Iohexol/administração & dosagem , Desenho de Prótese , Intensificação de Imagem Radiográfica/métodos , Stents , Tomografia Computadorizada por Raios X/métodos
6.
Korean Journal of Radiology ; : 150-155, 2009.
Artigo em Inglês | WPRIM | ID: wpr-60036

RESUMO

OBJECTIVE: This study was designed to investigate the effect of administration of warmed contrast material (CM) on the bolus geometry and enhancement as depicted on coronary CT angiography. MATERIALS AND METHODS: A total of 64 patients (42 men, 22 women; mean age, 56 years) were randomly divided into two groups. Group 1 included 32 patients administered CM (Omnipaque [Iohexol] 350 mg I/ mL; Nycomed, Princeton, NJ) saline solutions kept in an incubator at a constant temperature (37degrees C). Group 2 included 32 patients administered the CM saline solutions kept at constant room temperature (24degrees C). Cardiac CT scans were performed with a dual source computed tomography (DSCT) scanner. For each group, region of interest curves were plotted inside the ascending aorta, main pulmonary artery and descending aorta on test bolus images. Using enhancement values, time/enhancement diagrams were produced for each vessel. On diagrams, basal Hounsfield unit (HU) values were subtracted from sequentially obtained values. A value of 100 HU was accepted as a cut-off value for the beginning of opacification. The time to peak, the time required to reach 100 HU opacification, maximum enhancement and duration of enhancement above 100 HU were noted. DSCT angiography studies were evaluated for coronary vessel enhancement. RESULTS: Maximum enhancement values in the ascending aorta, descending aorta and main pulmonary artery were significantly higher in group 1 subjects. In the ascending aorta, the median time required to reach 100 HU opacification during the test bolus analysis was significantly shorter for group 2 subjects than for group 1 subjects. In the ascending aorta, the descending aorta and main pulmonary artery, for group 1 subjects, the bolus geometry curve shifted to the left and upwards as compared with the bolus geometry curve for group 2 subjects. CONCLUSION: The use of warmed CM yields higher enhancement values and a shorter time to reach maximum enhancement duration, resulting in a shift of the bolus geometry curve to the left that may provide optimized image quality.


Assuntos
Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Meios de Contraste/administração & dosagem , Angiografia Coronária , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Injeções Intravenosas , Iohexol/administração & dosagem , Estudos Prospectivos , Temperatura , Tomografia Computadorizada por Raios X
7.
Korean Journal of Radiology ; : 520-525, 2008.
Artigo em Inglês | WPRIM | ID: wpr-43027

RESUMO

OBJECTIVE: This study was designed to determine the optimal mixture ratio of gadolinium and iodinated contrast agent for simultaneous direct MR arthrography and CT arthrography. MATERIALS AND METHODS: An in vitro study was performed utilizing mixtures of gadolinium at six different concentrations (0.625, 1.25, 2.5, 5.0, 10 and 20 mmol/L) and iodinated contrast agent at seven different concentrations (0, 12.5, 25, 37.5, 50, 75 and 92-99.9%). These mixtures were placed in tissue culture plates, and were then imaged with CT and MR (with T1-weighted sequences, proton-density sequences and T2-weighted sequences). CT numbers and signal intensities were measured. Pearson's correlation coefficients were used to assess the correlations between the gadolinium/iodinated contrast agent mixtures and the CT numbers/MR signal intensities. Scatter diagrams were plotted for all gadolinium/iodinated contrast agent combinations and two radiologists in consensus identified the mixtures that yielded the optimal CT numbers and MR signal intensities. RESULTS: The CT numbers showed significant correlation with iodinated contrast concentrations (r = 0.976, p < 0.001), whereas the signal intensities as measured on MR images showed a significant correlation with both gadolinium and iodinated contrast agent concentrations (r = -484 to -0.719, p < 0.001). A review of the CT and MR images, graphs, and scatter diagram of 42 combinations of the contrast agent showed that a concentration of 1.25 mmol/L gadolinium and 25% iodinated contrast agent was the best combination for simultaneous CT and MR imaging. CONCLUSION: A mixture of 1.25 mmol/L gadolinium and 25% iodinated contrast agent was found to be optimal for simultaneous direct MR arthrography and CT arthrography.


Assuntos
Artrografia , Meios de Contraste/administração & dosagem , Gadolínio/administração & dosagem , Iohexol/administração & dosagem , Imageamento por Ressonância Magnética , Meglumina/administração & dosagem , Compostos Organometálicos/administração & dosagem , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
8.
Korean Journal of Radiology ; : 286-294, 2007.
Artigo em Inglês | WPRIM | ID: wpr-211225

RESUMO

OBJECTIVE: We wanted to evaluate the mural changes by CT on the follow-up examination of patients with active Takayasu arteritis. MATERIALS AND METHODS: The study included 18 patients, (4 males and 14 females), with active Takayasu arteritis. A total of 44 CT examinations were done during the follow-up period (mean: 55.6 months). At the time of the last follow-up CT, the disease, on the basis of the erythrocyte sedimentation rate (ESR), was found to be inactive in five patients and the disease was active and persistent in 13 patients. The thickness and CT attenuation of the aortic wall on the precontrast, arterial and venous phases were measured on the initial and the follow-up CT examinations. The ratio of the mural attenuation over that of the back muscle on the initial CT was compared with the ratio found on the follow-up CT. RESULTS: The initial CT findings included high density and calcifications of the aortic wall in the precontrast images and a thickened wall with enhancements in the arterial and the venous phases. A low-attenuation ring was demonstrated in the venous phase in 15 patients (83%). On the follow-up evaluation, the mean mural thickness decreased significantly from 4.1 mm to 2.4 mm. The mean mural attenuation ratio in the venous phase decreased significantly from 1.9 to 1.3 (p = 0.001). The low attenuation ring was identified in seven patients (39%) who had only with active, persistent Takayasu arteritis. CONCLUSION: The mural changes demonstrated by the follow-up CT evaluations for the patients with active Takayasu arteritis included a decrease of the mural thickness and enhancement, disappearance of the low-attenuation ring on the venous phase, and an increase of the mural attenuation and calcification on the precontrast phase.


Assuntos
Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Aortografia , Sedimentação Sanguínea , Meios de Contraste/administração & dosagem , Seguimentos , Iohexol/administração & dosagem , Artéria Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Arterite de Takayasu/diagnóstico por imagem , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA